MAIN TECHNICAL CHARACTERISTICS OF PRE-ENGINEERED BUILDINGS



Pre-Engineered Building system has been elaborated for those who value time.

The basis of steel buildings of Zamil Steel is frame with variable cross-section. The weight of such system is not more than 37 kg/m sq. This building construction allows finishing walls and roofs with any traditional and modern materials - façade glassing, aluminum composite panels, siding, brick cladding etc. If it is necessary it can be installed lifting equipment, like monorail, suspension and supporting beam, compressors for refrigerators, production mechanisms and equipment.

Pre-Engineered buildings of Zamil Steel are projected in full conformity with clients’ demands.

 

BASIC PARAMETERS


Building Width:
No matter what primary framing system is used, the building width is defined as the distance from outside of eave strut of one sidewall to outside of eave strut of the opposite sidewall. Building width does not include the width of Lean-To buildings or roof extensions.

 

Building Length:
The distance between the outside flanges of endwall columns in opposite endwalls is the building length. It is a combination of several bay lengths.

Building Height:
Building height is the eave height which usually is the distance from the bottom of the main frame column base plate to the top outer point of the eave strut. When columns are recessed or elevated from finished floor, eave height is the distance from finished floor level to top of eave strut.

Roof Slope (x/10):
This is the angle of the roof with respect to the horizontal. The most common roof slopes are 0.5/10 and 1/10. Any practical roof slope is possible.

End bay length:
The distance from outside of the outer flange of endwall columns to center line of the first interior frame column.

Interior bay length:
The distance between the center lines of two adjacent interior main frame columns. The most common bay lengths are 6 m, 7.5 m and 9 m.

Design Loads:
Unless otherwise specified Zamil Steel pre-engineered buildings are designed for the following minimum loads:

Roof Live Load: 0.57 kN/m2 Design Wind Speed: 110 km/h

Design for snow loads, earth quake loads, collateral loads, crane loads or any other loading condition, if required must be specified at the time of request for quotation.